Furuno FSV-84 User Manual Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 95
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
3-3
3. Remove the cover of the raise/lower control box and use a multimeter to measure the
following voltages:
Terminal Terminal No. Voltage
TB-C101 (1) – (2)
(2) – (3)
(1) – (3)
220 VAC
220 VAC
220 VAC
4. In the raise/lower control box, set the TEST/NORMAL switch to TEST. Press the
[DOWN] switch to confirm that the transducer lowers. Also, while the transducer is being
lowered, check that the MD LED lights when the MD L. SW kicks. Note that the MD L.
SW does not stop the transducer when the TEST/NORMAL switch is in the TEST
position.
OFF
TEST
NORMAL
5V
L.SW
UP MD DN
UP DOWN
Control unit (in hull unit)
5. Press and release the [DOWN] switch. Confirm that the transducer stops at the moment
the switch is released.
6. Press the [DOWN] switch again. Confirm that the transducer stops at the moment the
lower limit switch kicks.
7. Confirm that the [UP] switch operates in a similar manner.
8. Check that LEDs on the panel of the raise/lower control box light as follows:
1) UP, MD and DN LEDs light when corresponding limit switch is kicked.
2) UP and DN LEDs light while UP and DOWN switches are pressed and extinguish when
the switches are released.
9. Set the TEST/NORMAL switch to NORMAL.
10. At the control unit, press the
ª
(mid position) switch. Confirm that the lamp above the
switch blinks while the transducer is being lowered, a short beep sounds when the mid
limit switch kicks, and the lamp lights when the transducer is lowered to the mid position.
11. Press the
ª
switch (fully lowered position). Confirm that the lamp above the switch
blinks while the transducer is being lowered, a short beep sounds when the mid limit
switch is kicked, and the lamp lights when the transducer is fully lowered.
12. Press the OFF switch. Confirm that the transducer is completely retracted and then the
power is turned off.
13. Press the
©
switch. Confirm that the lamp above the switch blinks while the transducer
is being raised, a short beep sounds when the mid limit switch is kicked, and the lamp
lights when the transducer is fully raised.
14. With the transducer lowered (mid or fully lowered), confirm that the transducer is raised
when
©
or the OFF is pressed.
Page view 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 94 95

Comments to this Manuals

No comments