2-18
FUSE FUSE
F601 F602
INPUT
(TB-B101)
FUSE
F601 F602
100V
110V 20A 20A
115V
220V
230V
10A 10A
2.7 Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a
10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions and
fuses as below.
Input voltage
Set the toggle switches S603, S604 and S605 according to input voltage, referring to the
table below.
Input
(TB-B101)
S603 S604 S605 Default setting
100 VAC L L L
110 VAC H L L
115 VAC H H L
220 VAC H L H
230 VAC H H H Default setting
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table below.
Fuse
Input
(TB-B101)
F601 F602
Default
setting
100 VAC
110 VAC
115 VAC
20A 20A
220 VAC
230 VAC
10A 10A
Default
setting
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
Marking the label
After setting toggle switches and changing the fuses,
mark the label on the inside of the cover with the
voltage that applies. In the example shown right, 100
V is marked so 20A fuses must be used.