2. WIRING
14
4. Connect the transducer cable to the WAGO connector, following the instructions in the figure
below and the interconnection diagram. (The opener for the WAGO connector is attached in-
side the equipment. See the figure above.)
5. Unfasten the two screws labeled Screw A in the figure below.
6. Loosen the two screws labeled Screw B and slide cable clamp upward.
7. Pass the transducer cables through the cable entrance and connect their WAGO connectors
to respective terminals inside the equipment.
8. Slide the cable clamp downward and tighten screws B and A in that order to fasten the cable
clamp.
1. Twist conductors.
2. Insert opener as directed and press it down.
3. Insert core to hole.
4. Release opener.
5. Pull the core to make sure it is correctly inserted.
Opener (attached inside the equipment)
Core
Twist.
Push
Screw A
Screw B
Cable
clamp
Clamping
plate
Transducer cable
Page view 20