www.furuno.co.jpInstallation Manual UAIS TRANSPONDER FA-150 SAFETY INSTRUCTIONS...
4 • When coaxial cable RG-10U/Y (shipyard supply) is used, attach the coaxial plug M-P-7 (dockyard supply) as shown
5How to attach the plug M-P-7 Lay the coaxial cable and attach an M-type plug (if necessary) to the cable as follows. 1. Remove the sheath by 30
6 Mounting procedure 1. Dismount the bottom cover, cut the cable-tie inside the unit and take out the coaxial connector attached to the combined bo
7StanchionThetopofthestanchioncomesintocontactwiththeflange. Installing distributor unit DB-1 The length of the cable between the distribut
81.2 Monitor Unit The monitor unit can be installed on a desktop or flush mounted in a panel. Install it on the chart table or near the steering pla
9F type Use the optional flush mount kit OP20-29. Name Type Code No. Qty Cosmetic panel 20-016-1051 100-251-370-10 1 Self-tapping screw 5x20 000-1
101.3 UAIS Transponder Mount the transponder, where it is protected from rain and water splash. This unit can be installed on a bulkhead. Install it
111.4 Power Supply (option) When selecting a mounting location for the unit, keep the following in mind: • Keep the unit out away from areas subje
122. WIRING 2.1 Connection Connect the equipment, referring to the interconnection diagram at the back this manual. GPS AntennaGSC-001 or GPS-017S
13EXT ALM: Connect ship's alarm system.DISP: Connect the monitor unit.COM4COM2COM3COM1DC (-)DC (+)COM6COM5 Internal ports of the Transponder CO
The paper used in this manualis elemental chlorine free.・FURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,Nishinomiya, 662-8580, JAPANTelephone :
14*: Waterproofing connectors Wrap connector with vulcanizing tape and then vinyl tape. Bind the tape end with a cable-tie. Waterproofing connector
15Cable connection at transponder Fabrication of cables TTYCS-4 and TTYCS-1Q L6Removepaintby50mm.VinyltapeShield4550Cutvinylsheath.Exposecore
16Fabrication of power cable DPYC-2.5 40 mm: Peel paint.TapingArmor50 mm6 to7 mmVinyl sheathClamp here by cable clamp.
172.2 Changing Ship’s Mains Specifications The power supply PR-240 is shipped ready for connection to a 200-230 VAC ship’s mains. If the ship’s main
18 3. SETTING AND ADJUSTMENT After installing the equipment, set up the own ship’s static information (MMSI, IMO number, ship’s name, call sign,
194. SET MMSI is selected; press the [ENT] key to display the SET MMSI window. NAME:C. SIN: MMSI: 000000000 IMO NO: 000000000 QUIT [MENU][SET MM
203.2 Setting GPS Antenna Position 1. Open the INITIAL SETTINGS window, referring to page 18. 2. Press ▲ or ▼ key to choose SET INT ANT POS. and
213.3 Setting Ship Type 1. In the INITIAL SETTINGS window, press the ▲ or ▼ key to choose the SET SHIP TYPE and press the [ENT] key. [SET SHIP TYPE]
22 2. SET COM PORT is selected; press the [ENT] key. 3. Select an appropriate port among COM1, COM2, COM3, COM4, COM5 and COM6. If you choo
23The table below shows the ports and corresponding items to be set. Port and data format/data transmission rate Port External device (MODE) Format/
iSAFETY INSTRUCTIONSWARNINGTurn off the power at the switchboardbefore beginning the installation.Fire or electrical shock can result if thepower is
24Priority setup 1. Press ▲ or ▼ to choose SET PRIORITY at the SET I/O PORT sub-menu and press the [ENT] key. [SET PRIORITY]L/L, COG, SOGHDGROT Q
254. ATTACHING LAN KIT (OPTION) To connect to PC network or NAVNET 3D network, the optional LAN kit is required. Name: LAN kit Type: OP24-8 Code no.
26Setting LAN port for PC network 1. Press the [MENU] key, choose INITIAL SETTING, enter password, choose SET I/O PORT and press the [ENT] key to s
274. Press the [ENT] key, enter sub net mask in the SUB NET MASK field and press the [ENT] key. (Setting range: 000.000.000.000 to 255.255.255.255)
285. IEC 61162-1/2 DATA SENTENCES IEC 61162-1/2 format data is input or output from the data port COM1-COM6. The table below shows the input/output
29Input data/Sentences Sentence (Priority) Contents ABM Addressed binary and safety related message ACA AIS regional channel assignment message AC
%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..#6+
%1&'016;2'%2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..
%1&'016;2'(2⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105#%%'5
Antenna Cable Set CP20-02700 (004-381-160) CP20-02710 (004-381-170)A-8%1&'016;2'52+6'/010#/'1(2#46
iiSYSTEM CONFIGURATION : Standard : Option GPS/VHFcombined antennaGVA-100GPS antennaGSC-001GPA-017SDistributor unitDB-1VHF antennaPower supplyPR-2
Antenna Cable Set CP20-00300 (000-041-938) CP20-00310 (000-041-939)A-9
Y. HataiD-1
Y. HataiD-2
Y. HataiD-3
Y. HataiD-4
Mar,27'07 R.EsumiD-5
May 20 '03D-6
Feb.22'05D - 7
Jan. 9, '03D - 8
Apr.20'07 R.EsumiD-9
iiiEQUIPMENT LISTS Standard supply No. Name Type Code no. Qty Remarks 1 UAIS Transponder FA-1501 - 1 2 Monitor Unit FA-1502 - 1 GSC-001 -GPS A
Feb.02'05D-10
Nov.28'03D-11
Oct.02'03D-12
Y. HataiD-13
3412 56TYPE名前NAMEkgDWG. No.SCALEAPPROVEDDRAWNCHECKEDMASSCBDAIEC61162-2: 38.4KBPSIEC61162-1: 4800BPSFA-150U-AIS TRANSPONDERINTERCONNECTION DIAGRAM相互結線図
ivOptional supply No. Name Type Code no. Remarks 1 Monitor unit FA-1502 - CP20-02700 004-381-160 8D-FB-CV(30m)+CP20-02701 2 Antenna cable set
11. MOUNTING NOTICEDo not apply paint, anti-corrosive sealant or contact sprayto coating or plastic parts of the equipment. Those items contain organ
2How to attach the connector N-P-8DFB for cable 8D-FB-CV Outer SheathArmorDimensions in millimeters.Inner Sheath ShieldRemove outer sheath and armor
31.1.2 VHF antenna Location The location of the mandatory AIS VHF-antenna should be carefully considered. Digital communication is more sensitive t