Mounting procedure for tabletop, overhead and
bulkhead mounting
1. Using the hanger as a template, mark fixing holes in the mount-
ing location.
2. Fix the hanger to the mounting location with 4 sets of tapping
screw, washer, space and two kinds of bushing.
3. Screw the knob bolts with washers into the transceiver unit.
4. Set the transceiver unit to the hanger and tighten knob bolts.
All dimensions in millimeters.
For added support, fasten hanger with nuts, bolts and wash-
ers (local supply) instead of wood screws.
Leave sufficient space at the sides and rear of the unit to
provide easy access for maintenance and service. The mini-
mum service clearance is shown in the figure.
Figure 2 Mounting dimensions for tabletop, overhead and bulkhead
mounting
230
258
108
119
6-φ7.5
95 95
150
89
394
463
80
80
155
150