SAFETY INSTRUCTIONS....................... i
SYSTEM CONFIGURATION ................. iii
EQUIPMENT LISTS .............................. iv
1. Mounting ........................................... 1
1.1 Monitor Unit/Control Unit .........................1
1.2 Transceiver Unit .......................................6
1.3 Hull Unit ...................................................9
1.4 Interface Unit..........................................21
1.5 Motion Sensor MS-100 (option).............22
2. Wiring .............................................. 23
2.1 Wiring among Units................................23
2.2 Transceiver Unit .....................................26
2.3 Hull Unit .................................................29
2.4 Interface Unit..........................................30
3. ADJUSTMENTS ...............................31
3.1 General Checks..................................... 31
3.2 TX Frequency Checking........................ 32
3.3 Heading Adjustment/Soundome Setting
......................................................... 34
3.4 Adjustment of Motion Sensor ................ 37
3.5 System Back Up.................................... 38
3.6 Setting of Interface Unit......................... 40
Input/Output Description.................... 41
PACKING LISTS ................................ A-1
OUTLINE DRAWINGS ....................... D-1
INTERCONNECTION DIAGRAMS..... S-1
Installation Manual
SEARCHLIGHT SONAR CH-250
www.furuno.co.jp
Page view 0
1 2 3 4 5 6 ... 78 79

Summary of Contents

Page 1 - SEARCHLIGHT SONAR CH-250

SAFETY INSTRUCTIONS... i SYSTEM CONFIGURATION ... iii EQUIPMENT LISTS ... iv 1. Mountin

Page 2 - (YOSH ) CH-250

viii Cables for Installation materials Code no. Specification (Cable between unit) Type Monitor unit (or IF) and Transceiver unit Transceiver un

Page 3 - SAFETY INSTRUCTIONS

1 1. Mounting NOTICEDo not apply paint, anti-corrosive sealantor contact spray to coating or plastic parts of the equipment. Those items contain or

Page 4 - 0.80 m 0.55 m

2 2. For unibody mounting; a) Fasten the bracket at the rear of monitor and control units with four binding screws (M4x10). 11223344Bracket (rear

Page 5 - SYSTEM CONFIGURATION

3 Flush mounting Flush mounting for unibody (Type: OP06-16, Code no.: 006-556-300) Name Type Code No. Qty Remarks Fixing metal 06-021-1311-2 100-

Page 6 - EQUIPMENT LISTS

4 Hex. BoltsFixing Metal Flush mounting for control unit Type: OP02-83-1.5, Code no.: 001-413-600 (1.5 m cable) OP03-83-5, Code no.: 001-413-610

Page 7 - Hull Unit (1)

5 1.1.4 Control unit On blackbox type, fix the control unit to the mounting plate (supplied as accessories). See the parts list of FP06-01120 and

Page 8 - Hull Unit Standard Supply

6 1.2 Transceiver Unit 1.2.1 General mounting considerations • The mounting location should be well ventilated and dry. • The unit can be mounte

Page 9 - Tank guide

7 Wealding beadWealding bead1/21/3Within 1 meter Installation location for hull unit • Select a place where interference from the transducers of o

Page 10 - Options

8 For small FRP ship For small FRP ship retraction tank should be 2 degrees against ship’s draft. Therefore, this creates high water pressure in th

Page 11 - 1. Mounting

9 1.3.4 Assembling and mounting of hull unit The hull unit is shipped as the parts shown in the hull unit kit on Equipment Lists (page iv and afte

Page 12 - MOUNTING

The paper used in this manualis elemental chlorine free.・FURUNO Authorized Distributor/Dealer9-52 Ashihara-cho,Nishinomiya, 662-8580, JAPANTelephone :

Page 13 - Fixing metal

10 WARNINGWARNINGHex. bolt (M10X30)Spring washerFlat washerFlat washerNutTrunnion pinRaise/lowersectionShaft sleeve Shaft sleeve and raise/lower dr

Page 14 - 1.1.3 Blackbox type

11 4. Fully screw main shaft into the soundome neck, and then unscrew by four turns. Coat threads with adhesive (HIGH SUPER). Main ShaftGrasp the

Page 15 - 1.1.4 Control unit

12 7. If the gap at a side is more than 0.5 mm, install a shim to make the gap within 0.5 mm. a) Unscrew four M10x50 bolts. b) Unscrew four coun

Page 16 - 1.3 Hull Unit

13 The table below shows tank length and necessary shim thickness. In addition, the shim thickness shown is for one side. For example, when cutting

Page 17 - 1.3.3 Transducer tank

14 8. Apply THREE BOND 1104 to the inside of tank guide. And then, fasten tank guide at the neck* of the main shaft securely with M10X80 bolts. B

Page 18 - Mounting of transducer tank

15 11. Face the bow mark on the soundome with the bow mark on the shaft sleeve, and then fix the main shaft with and shaft retainer. 12. Fix the

Page 19 - Lt and cut off the

16 Protection spongeRotate 4 or 5 turns by hand to make sure that turning mechanisms are functioning properly.O-ringRemove.Socket head cap screw10p

Page 20 - Flat washer

17 CAUTIONKeep oil away from eyes. Where protective goggles when working with the oil. The oil cause inflammation of the eyes.Do not touch the oil.

Page 21 - (HIGH SUPER)

18 When the soundome is painted to keep marine life off the transducer, observe the following precautions: • Use only anti-fouling paint type MARI

Page 22 - Unscrew four M10x50 bolts

19 22. Fix the shaft sleeve and retraction tank with hex bolts, flat washers and spring washers. 10 mm15 mm1-2 mmBowMain shaftJubilee clipHex bolt

Page 23 - Shim thickness

i WARNINGELECTRICAL SHOCK HAZARDDo not open the equipment.Only qualified personnelshould work inside theequipment.Be sure no water leaks in at the

Page 24 - Tank guide attachment

20 Checking manual raise/lower of soundome with hand crank Perform this check after all wiring has been completed. CAUTIONTurn the main power off

Page 25 - Hex. bolt

21 1.4 Interface Unit For the blackbox type, the interface unit is shipped as standard. 1.4.1 General mounting considerations • The mounting lo

Page 26 - Ball wrench

22 1.5 Motion Sensor MS-100 (option) The MS-100 measures ship’s pitching and rolling angles with sensor using the principles of the gyroscope. The

Page 27 - Soundome

23 2. Wiring 2.1 Wiring among Units • The figure on the next page shows wiring among units. • The signal cables are fitted with connectors. Conn

Page 28 - Paint area

24 HULL UNTSPEAKERDATA/VIDEO OUTMOTION SENSOR12-32VDC12/24-32VDC12-32VDCSpeaker(w/cable)Motion SensorRemoteControlerNavigation Equipment06S4078(5/1

Page 29 - Hex bolt

25 HULL UNTSPEAKERDATA/VIDEO OUTMOTION SENSOR12-32VDC12-32VDCSpeaker(w/cable)Motion senserExternal monitorNavigation EauipmentNote1: Two interface

Page 30 - • Welding bead

26 2.2 Transceiver Unit Connect the cables as figure in below. Remove the cover of the power terminal board. 06P024106P024006P0242J1J6J206S4080Hull

Page 31 - 1.4 Interface Unit

27 2.2.1 Synchronizing Transmission with Echo Sounder or Other Sonar To synchronize transmission of the CH-250 with an echo sounder or other type

Page 32 - 1.5.2 Mounting procedure

28 5TX RATEEXT. MAX(EXT., 1-10)MIN TX rate setting window 5. Press the ["] to select EXTERNAL. 6. Press the [MENU] key to close the user men

Page 33 - 2. Wiring

29 2.3 Hull Unit Pass the cables to 06P0426 Board through the cable protectors. 06P024606P0243J2J1J3J1J2TB2Cable from transducer06S4081Cable from t

Page 34 - Wiring, with monitor

ii CAUTIONObserve the following compass safedistances to prevent deviation of amagnetic compass:Ground the equipment toprevent electrical shock and

Page 35 - 12-32VDC

30 2.4 Interface Unit EarthNAVControl unit cable06S4079VGAmonitorMonitor unit cable06S4078Transceiver unit cable06S4078Connect to ship's earth

Page 36 - 2.2 Transceiver Unit

31 3. ADJUSTMENTS 3.1 General Checks Table 3-1 General checks On-keel InstallationOff-keel InstallationWithin 1 m1 cm400 stroke: Minimum 30 cm250 s

Page 37 - Menu setting

32 Table 3-1 general checks (con’t) Check Item Check point, Rating Wiring check • All cables are correctly connected. • All lead wires are tight

Page 38 - Transceiver unit

33 RANGE-SONAR MODERANGE-VERTICAL MODERANGE-E/S MODEADJ MOTION SENSOR TX FREQ ADJUSTTESTTEST PATTERNDEMO MODEDEFAULT: SELECT: MENU DISPLAY MENU: EN

Page 39 - 2.3 Hull Unit

34 3.3 Heading Alignment/Soundome Setting Heading alignment The heading line can be compensated through the system menu ( –30° to +30°). 1. Locate

Page 40 - 2.4 Interface Unit

35 RANGE-SONAR MODERANGE-VERTICAL MODERANGE-E/S MODEADJ MOTION SENSOR TX FREQ ADJUSTTESTTEST PATTERNDEMO MODEDEFAULT: SELECT: MENU DISPLAY MENU: EN

Page 41 - 3. ADJUSTMENTS

36 OFF 10sec 30sec 1min 3min 6minOFF FLOW FROM FLOW TOSHIP'S L/L SHIP'S LOP CURSOR L/LPOSITION :CURRENT DATA :HEADING INDICATION : T

Page 42 - 3.2 TX Frequency Checking

37 3.4 Adjustment of Motion Sensor When the ship has a semi-permanent inclination, offset it as follows. 1. Press the [MENU] key to display the

Page 43

38 6. Press [] [] to select ROLL ANGLE or PITCH ANGLE. 7. Press [] [] to adjust (-10° to +10°). By using a clinometer or other means, measure s

Page 44 - Heading alignment

39 RANGE-SONAR MODERANGE-VERTICAL MODERANGE-E/S MODEADJ MOTION SENSOR TX FREQ ADJUSTTESTTEST PATTERNDEMO MODEDEFAULT: SELECT: MENU DISPLAY MENU: EN

Page 45 - : SELECT

iii SYSTEM CONFIGURATION HULL UNITSPEAKERDATA/VIDEO OUTMOTION SENSOR12-32 VDCNote 1Note 212-32 VDCSpeakerMotion SensorVGA Ext.MonitorControl UnitDi

Page 46

40 3.6 Setting of Interface Unit Set DIP switch S1 in the interface unit as follows. • The monitor unit MU-100C or the interface unit is connecte

Page 47

41 Input/Output Description The CH-250 can receive/transmit the following sentences in NMEA 0183 format. Input • GLL: GPS position • VTG: G

Page 48 - 3.5 System Back Up

This page is intentionally left blank.

Page 49 - ** SYSTEM BACK UP**

㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀#5: %*%*'0#/'176.+0'&'5%4+26+10%1&'ͳ36;࡙࠾࠶࠻ 70+6ᠲ૞ㇱ%10641.70+6%*

Page 50

%1&'016;2'⇛ޓޓ࿑176.+0'ฬޓޓ⒓0#/'ᢙ㊂36;↪ㅜ㧛஻⠨4'/#4-5⇟ภ01ဳฬ㧛ⷙᩰ&'5%4+26+105+056#..#6+10/#6'4+#.5Ꮏ੐᧚ᢱ

Page 55

Y. HataiD-2A

Page 56

iv EQUIPMENT LISTS Standard Supply Name Type Code no. Qty Remarks Control Unit/ Monitor Unit CH-252/ MU-100C 1 Not supplied with blackbox type Co

Page 60

Y. HataiD-5

Page 63

Takahashi T. Takahashi T. D-8D-8

Page 67

v Hull Unit (1) Spec. Code no. Type Stroke Power Frequency Shaft Cable 000-068-515 CH-254-1-60-22-35 60 kHz 000-068-516 CH-254-1-88-22-35 88 kHz

Page 69

Y. HataiD-13

Page 76

TITLENAME名称kg相互結線図INTERCONNECTION DIAGRAMDRAWNCHECKEDAPPROVEDSCALEMASSFURUNO ELECTRIC CO., LTD.DCBA654321CH-250/S129103456781112TIP1TIP3TIP2TIP4TRP1TR

Page 77

TITLENAME名称kgDRAWNCHECKEDAPPROVEDSCALEMASSDWG No.FURUNO ELECTRIC CO., LTD.DCBA654321相互結線図INTERCONNECTION DIAGRAMCH-250/SカラーLCDサーチライトソナー(I/Fユニット使用)*3)コ

Page 78 - FURUNO ELECTRIC CO., LTD

vi Hull Unit Standard Supply Name Type Code no. Qty Remarks CH-2541 - Raise/lower Drive Unit CH-2551 - 1 set Soundome CH-2542 - 1 set See th

Page 79

vii Shaft parts Name Type Code no. Qty Remarks Pipe cap SHN-0011-0 661-400-110 1 Jubilee Clip 1X28-41 000-801-857 1 Hex. bolt M10X35 SU