1-2Installation precaution for S-band scanner unitIf an S-band scanner unit is mounted near the end of a platform to provide suffi-cient rotation cle

Page 3 - SAFETY INSTRUCTIONS

1-3How to lift scanner unit1. Fix the scanner radiator to the scanner unit chassis.2. Attach the lifting fixtures and collars as shown in Figure 1-2

Page 4

1-4Scanner unit assemblingThe scanner radiator and the scanner housing are shipped in separate packages.Assemble them as below. The scanner unit may

Page 5 - TABLE OF CONTENTS

1-5Fastening the scanner unit to the mounting platformSee the figure on the next page for scanner unit mounting.1. Referring to the scanner outline d

Page 6 - EQUIPMENT LISTS

1-6Seal washerCorrosion-proofrubbermatCoat with silicone sealant afterfastening ground wire.Ground wireScanner bodyHex boltHex nutORGround wireCoat w

Page 7 - Optional Equipment

1-71.2 Display UnitBefore mounting the display unitIf Gyro Converter GC-8 (option) is to be used, install and setup the GYRO CON-VERTER Board before

Page 8 - SYSTEM CONFIGURATION

1-84. While one person is holding the mounting base at the sides, pull the handle onthe underside of the control head to draw the display unit toward

Page 9 - MOUNTING

1-9CatchStopperStayFigure 1-10 Setting catch to hole in stayc)Release hand from stopper.Release stopper;fix stay.Figure 1-11 Stay fixed6. Fasten the

Page 10 - Pole for DF, etc

1-10J106J105J104J103J446J466J462J465*M3x8, 5 pcs.****Slide forward.M4x8, 2 pcs.Fixing hole (front)Fixing hole (rear)KnobFigure 1-12 How to remove th

Page 11 - How to lift scanner unit

1-11Separate type control head kit (Type: OP03-151, No.: 008-485-530)emaNepyTytQ.onedoCskrameR.yssAelbaCP1/P02BS642LU1218-041-0002249S30,m01teeFrebbu

Page 12 - Scanner unit assembling

Your Local Agent/DealerYour Local Agent/Dealer9-52 Ashihara-cho,9-52 Ashihara-cho,Nishinomiya, JapanNishinomiya, JapanTelephone :Telephone : 0798-65-2

Page 13

1-124. Unfasten the M4 screw fixing the ground terminal of the connection cable.5. Push the monitor forward until you hear a click.6. Unscrew four sc

Page 14

1-13Control head modification procedure1. Unfasten eight screws (M4X8) on the underside of the control head. Unplugconnectors P314, P312 and P317 fro

Page 15 - 1.2 Display Unit

1-14Connection of display unit to control head1. Attach the handle to the handle plate, using the screws for the handle andbottom cover of the contro

Page 16 - Figure 1-8 Display unit

1-151.3 Power Supply UnitThe Power Supply Unit PSU-004 does not contain usual operating controls. There-fore, it can be installed in any recessed pl

Page 17 - Figure 1-11 Stay fixed

This page is intentionally left blank.

Page 18 - Separating the control head

2-1WIRING2.1 Display UnitFabricating the power cable DPYCY-3.5 (JIS cable)1. Remove the vinyl sheath by 80 mm.2. Cut off jute tape wrapped around the

Page 19 - 3. Lower the monitor

2-2Leading in cables to the display unitThe cable clamp may be positioned inside the display unit (default arrangement),outside the display unit or a

Page 20

2-3Cable fed from outside display unit(B) Power clamp(Aluminum)(C) Signal clamp(Aluminum)(D) Rear clamp plate(A) Rear clamp baseBottom clamp front pl

Page 21 - Figure 1-15 Control head

2-4ConnectionsOpen the display unit and fix it with the stay. (For procedure see page 1-6.) Re-move the shield cover from the INT Board. Connect sign

Page 22 - Attachment of hood

2-5Connectors on the INT BoardTable 2-1 Connectors on the INT BoardemanlangiSnoemaNbcprotcennoC.onrotcennoCepytelbacilppAtnempiuqeskrameRlangiStupnIl

Page 23 - 1.3 Power Supply Unit

iSAFETY INSTRUCTIONSWARNINGWARNINGRadio Frequency RadiationHazardThe radar scanner emits electromagneticradio frequency (RF) energy which can beharmf

Page 24

2-6How to attach NH connector20mm1 Insert NH connectorwire into NH connectorhousing.2 Cut shrink tubingin 20 mm lengths andslip onto each wire.3 Sold

Page 25 - 2.1 Display Unit

2-73. Open the left side cover on the scanner unit with the hex wrench (supplied).4. Unfasten the cable gland for the multicore cable and remove the

Page 26 - (Display unit, rear view)

2-89. Remove the sheath of each conductor by 6 mm. Fix crimp-on lugs (FV1.25-4,blue, ø4) to each conductor. Make sure each connection is secure both

Page 27

2-9Terminal board fixing plate for RTB-801 Ground terminalFigure 2-13 Scanner unit, rear viewLocking wire saddleFigure 2-14 Scanner unit, rear view19

Page 28 - Connections

2-1020.Route the signal cable beneath the lower left side of the terminal board fixingplate for the RTB-801. Shorten conductors of the signal cable c

Page 29 - Connectors on the INT Board

2-1126.Check for miswiring, loose screws. Grease the fixing bolts for the cover, gas-ket, and tap holes in the scanner chassis. Attach the cover.When

Page 30 - 2.2 Scanner Unit

2-122.4 Power Supply UnitWire the unit as shown in the interconnection diagram.Thermal relayK2Relay K3Relay K1TBPTB12TBPTB13TBPTB11TBPTB14Photo No. 3

Page 31

3-1INITIALIZATION AND ADJUSTMENT3.1 Tuning InitializationTune the radar as follows: Press [RADAR MENU] [0] [0] [2] [0] [0] [0] [0] (TUNEINITIALIZE on

Page 32

3-23.4 Heading AlignmentYou have mounted the scanner unit facing straight ahead in the direction of thebow. Therefore, a small but conspicuous target

Page 33 - Locking wire saddle

3-33.5 Adjusting Sweep TimingSweep timing differs with respect to the length of the signal cable between thescanner unit and the display unit. Adjust

Page 34

iiCAUTIONObserve the following compass safedistances to prevent deviation of amagnetic compass:Ground the equipment toprevent electrical shock andmutu

Page 35 - When the de-icer is installed

3-43.7 Confirming Magnetron Heater VoltageMagnetron heater voltage is adjusted at the factory. Confirm that magnetron heatervoltage is within the pre

Page 36 - Photo No. 3148

3-5PCB 03P9243P801VR1Figure 3-7 Scanner unit, stern side view3.8 Initial Setting MenusThe INITIAL SETTING menu (four menus) and the OWN SHIP INFORMATI

Page 37 - INITIALIZATION AND ADJUSTMENT

3-6[INITIAL SETTING 1]1 [FUNCTIONS(4)]2 HL ALIGNEBL 0.0°3 TIMING ADJVRM 00.004 ANT HGT 5m/7m/10m/15m/20m/30mMORE5 LOG PULSE 200P6 [OWN SHIP INFORMATIO

Page 38 - 3.4 Heading Alignment

3-7OWN SHIP INFORMATION: Enter ship's characteristics; length, width, radarscanner position, navigation antenna position, turn rate, and speed ra

Page 39 - (3) Target pushed

3-8INITIAL SETTING4 menuKeying sequence: [RADAR MENU] [0] [0] [0] [2] [0] [0] [0]MODEL: Selects radar model.TYPE: Selects specification of radar. Sele

Page 40 - compartment

4-1INSTALLATION OF OPTIONAL EQUIPMENT4.1 Gyro Converter GC-8The Gyro Converter GC-8, incorporated inside the radar display unit, convertsanalog gyroc

Page 41 - 3.8 Initial Setting Menus

4-24) Connect the GYRO CONVERTER Board to the INT Board (cables suppliedwith GC-8) as shown below.INT Board GYRO CONVERTER BoardJ446

Page 42 - INITIAL SETTING1 menu

4-3Connection of external power supplyAn external power supply is necessary when the repeater signal is step-by-steptype and the step voltage is belo

Page 43 - INITIAL SETTING3 menu

4-4Setting method 1: by gyrocompass specifications1) Gyrocompass type 2) FrequencyGyrocompasstypeSW1-4SW1-5SW1-6JP1 Frequency SW1-7SW1-8RemarksAC syn

Page 44 - OWN SHIP INFORMATION menu

4-5Setting method 2: by make and model of gyrocompassrekaMsledoMnoitacificepSWS1-1WS2-1WS3-1WS4-1WS5-1WS6-1WS7-1WS8-1WS1-2WS2-2WS3-21PJ2PJ3PJ4PJ5PJON

Page 45 - BOARD 64P1106

iiiTABLE OF CONTENTSEQUIPMENT LISTS...ivSYSTEM CONFIGURATION...

Page 46 - J465 (6P) J1 (14P)

4-6Location of DIP switches, jumper wires on the GYRO CONVERTERBoard64P1106JP5, JP4(Supply voltage)JP2(Rotor voltage)JP3(Stator voltage)JP1(Gyro type

Page 47 - Default setting

4-74.2 ARP Board ARP-26The ARP Board ARP-26, which provides ARPA functions, is an optional circuitboard which is accommodated in the display unit of

Page 48 - 5) Ratio 6) Supply voltage

4-8ARP board adjustment1. Turn the GAIN, A/C SEA and A/C RAIN controls fully counterclockwise, andthen transmit on the 12 nm range.2. Connect a digit

Page 49

4-9Final checkConnect a gyrocompass and a log to the radar and place the radar under transmitstate. Confirm that LEDs CR9, CR10, CR11, CR12, CR15 and

Page 50

4-104.3 RP Board RP-26The RP Board RP-26, which providesvideo plotter functions, consists of a circuitboard and a card drive both of which are accomm

Page 51 - 4.2 ARP Board ARP-26

4-114. Unfasten the front panel from the display pedestal.5. Pass the connector from the card case through the hole in the display pedestal.Display p

Page 52 - ARP board adjustment

4-1210.Fasten the front panel on the display pedestal.11.Retract the stay to close the display unit.12.Fasten the right arm cover.Separate type contr

Page 53 - Final check

4-13M-card baseM-cardcase lidPan Head ScrewM2.6X5(2 pcs.)Display pedestalDisplay pedstalfront panelFigure 4-13 Display pedestal, front view5. Loosen

Page 54 - 4.3 RP Board RP-26

4-1410.Fasten the front panel of the display pedestal.11.Fasten the ground wire to the location shown in Figure 4-14.12.Close the monitor.4.4 Perform

Page 55 - Figure 4-10 Display pedestal

4-154.5 Alarm KitNecessary parts: OP03-156 (Code no. 008-500-650)The alarm kit mainly consists of a circuit board and connection cables, and pro-vide

Page 56 - Separate type control head

ivEQUIPMENT LISTSStandard SupplyemaNepyT.oNedoCytQskrameRtinUrennacSFA03NS-1rotaidaRFA63NS-6200-BSR-1reciedtuohtiwrohtiw,sissahcannetnA1300-BSR-8800-

Page 57

4-16J475J474J473J472J471J451AAPan-head ScrewM3X8, 4 pcs.Cable Tie CV-100,2 pcs.ALARM Board03P9262NH Connector03-1991(3P), 4 pcs.Pan-head screwM4X12 C

Page 67

vOptional EquipmentemaNepyT.oNedoCytQskrameRyalpsiDetomeR0108-DMF–1retrevnoCoryG2-8-CG025-644-800tes1redroetarapeShctiwsretnI7-JR–1hctiwsretnI8-JR–1r

Page 78

viSYSTEM CONFIGURATIONDISPLAY UNITRDP-124ARPA BoardARP-26NavigatorIEC 61162-1 (Input/Output)IEC 61162-1 (Input)Speed LogOPTIONPerformanceMonitorPM-5

Page 82

1-1MOUNTING1.1 Scanner UnitMounting considerations• The scanner unit is generally installed either on top of the wheelhouse or on theradar mast, on a